another way is to use the Select by warning in Analysis Log,then place the elements on a new layer.
1- Create a new layer for elements
2- Right-click in Analysis Log, and click "Select By Warning" and select the warning number 98731
3- Assign elements to new layer.
You can then turn off other layers.
Display thickness, and compare areas and adjust thickness.
You can then find and edit thickness for Dual Domain elements from Automatic to Specified.
Changing the thickness on a Dual Domain mesh
(Note: this is to be used with care, as for some cases could affect warp.
This can be used when experimenting with the flow pattern by allowing you to change the thickness in the study without ruining the integrity of the CAD geometry. This procedure should only be performed when running Fill+Pack analysis.
If a Cool or Warp analysis is going to be performed, the thickness change must be represented in the CAD model)
What you see can many times depend on that the Dual Domain elements are unmatched, and then inherit thickness neighboring elements.
经常做分析的人都会碰到各种各样的问题,如果遇到上述问题解决,请看解说,有产品需要分析的可扫我头像。